MCKARLEN · HCR · 50 Hz
HCR Series
Vertical multistage centrifugal pumps for water supply, pressure boosting, water treatment and clean industrial water circulation.


Applications and design
Water supply / boosting
Building and factory water supply. Select for flow, total head and inlet pressure.
Water treatment
Feed water for treatment systems. Check liquid composition and wetted materials.
Water circulation
Utility-water circulation. Hot-water service requires a suitable seal and material configuration.
Technical data and operating limits
| Pump design | Vertical multistage centrifugal; inlet and outlet at the same level |
|---|---|
| Liquid | Thin, clean, non-flammable and non-explosive; no solid particles or fibres |
| Standard temperature | −15 to +70°C |
| Hot-water configuration | +70 to +120°C; verify model-specific seal, materials and pressure |
| Materials | 304 / 316 versions by model and wetted component |
| Catalogue motor range | 0.37–110 kW; individual model power is listed in the selection tables |
| Environment | ≤40°C; assess motor derating above 1,000 m or 40°C |
| Pressure / duty | Inlet + shut-off pressure must remain below the model limit; check the duty curve and NPSH. |
Not for wastewater containing debris, fibres or sand. For chemicals, salt water or viscous liquids, supply composition, concentration and temperature before material and seal selection.
Technical documents
Pump selection / spare parts
Send flow, total head, liquid, temperature, inlet pressure and power supply. For replacement or spare parts, include the nameplate photo and connection dimensions.